Information Name: | QE65000 research level fluorescence measurement configuration Spectrometer |
Published: | 2015-05-21 |
Validity: | 3000 |
Specifications: | 1180g |
Quantity: | 24.00 |
Price Description: | |
Detailed Product Description: | Product description fluorescence measurement configuration QE65000 scientific grade spectrometer Features * quantum efficiency up to 90% - higher system sensitivity · Excellent UV response capability to meet the low brightness level · Conditions ? Onboard microcontroller applications · Plug and Play USB · Optical Platform ? Installation and Use Manual * Specifications scientific grade spectrometer QE65000 spectrometer will probe the latest technology, optical bench and electronics combine to provide extremely high sensitivity and spectral response of optical resolution, for scientific research provided strong It means. In the application under extreme low light conditions QE65000 apply to applications under low light conditions, fluorescence, Raman spectroscopy, DNA sequencing, astronomy and thin-film reflection. In complete fluorescence measurement system, PX-2 pulsed xenon light source is used to excite the CUV-ALL-way sampling stent samples. Ocean Optics also offers a solid-state secondary fluorescence standard STAN-FL-RED, can quickly and easily test and calibration system performance and stability. Quantum efficiency as high as 90% QE65000 spectrometer manufactured using a Hamamatsu FFT-CCD detector can be achieved (defined as the photon conversion efficiency of a photoelectron) up to 90% of the quantum efficiency. Unlike other spectrometers used in linear CCD detector area array CCD detector in the vertical direction 64 pixels, rely on the internal circuitry of the CCD signal is integrated to improve the signal to noise ratio (1200: 1) and the signal processing speed while linear CCD signal can only be handled by an external digital circuitry. Enhanced sensitivity of the system due to the full use of the area CCD slit height direction of the incident light, thereby greatly enhancing the QE65000 system sensitivity. In Ocean Optics spectrometer, by selecting different slit width control goes to the light intensity of the optical table. And now most of the spectrometer linear CCD detectors are used, so the slit height direction of the incident light system will not be fully utilized, while QE65000 research grade spectrometer is used in area array CCD, it is possible to collect more light, It is ideal for low brightness fluorescence applications. Physical Dimensions 182 mm x 110 mm x 47 mm Weight 1180 g (without power) detector detector Model Hamamatsu S7031-1006 back-thinned FFT-CCD detection range 200-1100 nm pixels 1024 x 58 (all pixels 1044 x 64); micron pixel size of 24.6 square signal to noise ratio of 1000: 1 (full signal) dark noise 2.5RMS electronic sensitivity when 400nm, 22 electrons / count value; at 250nm, 26 photons / count value of the optical platform design f / 14 kinds 4, Czerny-Turner optical focal length crossing symmetry incident and exit are 101.6mm focal length of the entrance aperture 5, 10, 25, 50, 100 or 200 μm slit width or fiber (no slit) optional raster a selection of different gratings, covering the ultraviolet to near-infrared filter options QFLV-QE and OF-1 long-pass filter to eliminate diffraction grating optical parameters depending on the wavelength range of the optical resolution of ~ 0.14-7.7nm FWHM SMA905 fiber optic connector type connector device with a single strand of optical fiber connected to the 0.22 aperture fiber 0.14 ~ 7.7nm resolution full wave at half maximum (FWHM) signal to noise ratio of 1000: 1 (at full signal) A / D converter resolution 16 3 RMS counts dark noise dynamic range 7.5 x 109 (system), 25,000: 1 (single operation) when the integration time 8ms ~ 15min 600nm optical drift of less than 0.08%; when 435nm to linearity correction after 0.4%> 99.8% electrical parameters power consumption 500mA, 5V DC (no Thermoelectric cooling) 3A, 5V DC (thermoelectric cooling) data transfer speed is scanned into memory: USB2.0 interface 7ms, USB1.1 interface is 18ms, 300ms serial port of the input / output 10 integrated user-programmable digital GPIO (General Purpose input and output interfaces) without autozero channel analog output without external box compatibility of data, HR4-BREAKOUT type trigger mode four kinds of transmission pulse transfer function delay function without connector 30-pin connector boot time of less than 5s dark current 25 ℃ Under 4000e / pixel / sec; 0 ℃ under 200e / pixel / sec computers connected operating system Windows 98 / Me / 2000 / XP operating system with USB interface Mac OS X or Linux operating systems; 32-bit Windows OS with serial Systems connected to the computer at 480 Mbps USB 2.0; RS-232 peripheral SPI at 115.2 K baud (3 now); internal I2C integrating circuit temperature and thermoelectric cooling temperature range of -15 ℃ ~ 50.0 ℃; no condensation point temperature control software, the lowest point temperature variation does not exceed +/- 0.1 ℃ ~~~~~~~~~~~~~~~~~~~~~~ lowest -15 ℃ within 2 of the set temperature stability when the ambient temperature is below 40 ℃ ~~~~~~~~~~~~~ welcome to inquire ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~,, |
Admin>>>
You are the 143936 visitor
Copyright © GuangDong ICP No. 10089450, Ocean Optical Co., Ltd. in Changchun All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 143936 visitor
Copyright © GuangDong ICP No. 10089450, Ocean Optical Co., Ltd. in Changchun All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility